A/LR(1)/LD/FD/NI/LP/LO/RF/NP/OS/GC/VN

Taxonomy string
A / LR (1) / LD / FD / OS / RF / LO / LP / VN / NP / GC / NI
Construction Type
LBM: Load Bearing Masonry
GPSS Building Category
A: Earthen Blocks or compressed stabilized soil blocks in mud mortar
Country
Nepal
Peru
GPSS Building Type
Taxonomy Parameters
Single storied

1. Height range

LR (1)

<p>Single story</p>

Low design

2. Seismic design level

LD

<p>- Fair construction quality and workmanship<br>- Few seismic enhancement measures<br>- Building designed for low lateral loads</p>

A: Earthen Blocks or compressed stabilized soil blocks in mud mortar

3. Main structural system

A

<p>- Buildings constructed of sun dried adobe bricks in mud mortar<br>- Walls are generally thick at about 500 mm in average</p>

Flexible diaphragm

4. Diaphragm type

FD

<p>- Roof/floor with insufficient in-plane stiffness</p><p>- Poor connection of the roof/floor to the lateral load resisting system</p>

Original structure

5. Effective seismic retrofitting

OS

<p>- Original structure, which undertook or not minor non-structural improvements and/or maintenance</p>

Rigid foundation

6. Foundation type

RF

<p>- Prevents large foundation deformations and anticipated failures</p>

Large openings

7. Wall openings

LO

<p>- Opening width in a wall between two consecutive cross walls is more than or equal to 0.35 times (0.25 times) the wall length in single-story (multi-story) building</p>

Long panel

8. Wall panel length

LP

<p>- Wall length is more than 12 times the wall thickness</p>

Vulnerable non-structural components

9. Non-structural components

VN

<p>- Building has non-structural components that can produce human casualties and economic losses such as: parapets, ceilings, tiles, pipes, infill, etc.</p>

No pounding

10. Seismic pounding risk

NP

<p>- Seismic gap between buildings at least 4% of the height of the shorter building where the expected collision occurs</p>

Good condition

11. Structural health condition

GC

<p>- Building structure is in overall good condition</p>

No irregularities

12. Structural irregularity

NI

<p>- Regular in plan and elevation</p>

Failure Modes
Corner Failure

Corner Failure

<p>Corner failure mainly occur in heavy stone masonry walls. The corners are pushed out and subjected to partial collapse. Cause of this failure mode are poorly interlocking of the wall and mortar with poor quality.&nbsp;</p>

Non-Structural Failure

Non-Structural Failure

<p>Overturning or damage of non-structural components (e.g. parapets, chimneys, etc.) due to lack of adequate anchorage/confinement.&nbsp;</p>

Diaphragm Failure

Diaphragm Failure

<p>Collapse or failure of floor/roof. Possible causes include inadequate connection of floor/roof to the lateral resisting system (e.g. walls, frames), insufficient in-plane stiffness (e.g. unbraced timber/steel trusses) of the floor/roof, etc.&nbsp;</p>

In Plane – Combined Shear/Flexural Failure

In Plane – Combined Shear/Flexural Failure

<p>Walls are divided into piers (i.e. vertical elements) and spandrels (i.e. horizontal elements) by openings (i.e. windows and doors) in the wall. This failure mode is a combination of shear, flexural rocking, and shear sliding failure.&nbsp;</p>

In Plane – Flexural Rocking Failure

In Plane – Flexural Rocking Failure

<p>Walls are divided into piers (i.e. vertical elements) &amp; spandrels (i.e. horizontal elements) by openings (i.e. windows and doors) in the wall. Flexural rocking usually occurs when material shear capacity is high, piers are slender, and compressive stress is low in the wall. Flexural cracking develops at the heel of the pier, leading to rotating behavior of the wall about the toe.&nbsp;</p>

In Plane – Shear Failure

In Plane – Shear Failure

<p>Walls are divided into piers (i.e. vertical elements) and spandrels (i.e. horizontal elements) by openings (i.e. windows and doors) in the wall. Diagonal cracking can develop in piers with relatively small aspect ratio (i.e. effective height by width ratio), leading to degraded strength of and potential shear sliding resulted offsets and overturn of the wall.&nbsp;</p>

In Plane – Shear Sliding

In Plane – Shear Sliding

<p>Walls are divided into piers (i.e. vertical elements) and spandrels (i.e. horizontal elements) by openings (i.e. windows and doors) in the wall. When pointing mortar fails under shear, horizontal or stair-stepped diagonal cracks are generated, which allow sliding to occur. This may lead to potential offsets and overturn of the wall.&nbsp;</p>

Out of Plane Failure

Out of Plane Failure

<p>Overturning of masonry walls leading to partial or full collapse of the wall, which may have combined tension failure of in-plane pier portions of perpendicular walls. Possible causes are lack of structural integrity to achieve box-like behavior (e.g. no band beams, flexible diaphragms, etc.), and/or mortar has poor cohesion and tension capacity.&nbsp;</p>